CE Certified · Factory Direct Manufacturer

EP-HGJ-B Wide-Mouth Jar Preform Heater — Mold Height 160mm, Neck Diameter 130/65mm

Preform heater for semi-automatic wide-mouth jar production lines. Neck diameter up to 130/65mm, mold height 160mm, 500–1,200 bph. Required component for all HGS semi-automatic machines producing wide-mouth jars. For standard narrow-neck bottles (neck ≤ 68mm), see EP-HGJ-CL. Requires three-phase power supply.

Description

Preform Heater · Wide-Mouth Jar · Neck Dia. 130/65mm · Mold Height 160mm · 500–1200 bph · Semi-Auto Line Component

EP-HGJ-B Wide-Mouth Jar Preform Heater

Preform heater for semi-automatic blow molding lines producing wide-mouth jar containers — neck diameter up to 130/65mm, mold height 160mm, 500–1,200 bph. A required component in every HGS semi-automatic line: HGS machines do not heat preforms internally; a separate HGJ heater must be paired with the blow molding machine.

HGJ-B vs HGJ-CL — Select by Neck Diameter

Both HGJ heaters serve semi-automatic blow molding lines. The only selection criterion is your bottle’s neck diameter. Selecting the wrong heater means the preform holder cannot accommodate your preform neck.

Parameter HGJ-B ← This Heater HGJ-CL
Application Wide-mouth jars Standard narrow-neck bottles
Max. Neck Diameter 130/65mm 68mm
Output 500–1,200 bph 200–2,100 bph
Preform Holder Positions 18/36 96
Select When Wide-mouth jar or large neck diameter Standard bottle, neck ≤ 68mm

Not sure which heater is correct for your bottle? Send us your bottle drawing with neck diameter specification and our engineering team will confirm the correct heater model.

EP-HGJ-B wide-mouth jar preform heater semi-automatic blow molding line component neck diameter 130mm mold height 160mm

What a Preform Heater Does — and Why It Is Required

In a two-step (RSBM) blow molding process — semi-automatic or fully automatic — PET preforms must be heated to the correct temperature before they can be stretched and blown into bottles. In fully automatic machines, the heating zone is integrated inside the machine. In HGS semi-automatic machines, the preform heating is handled by a separate, standalone heater unit — the HGJ series.

The HGJ-B heater holds preforms in a rotating carousel, exposing them to infrared heating lamps as they travel through the heating zone. When preforms reach the correct temperature — typically 95–115°C at the bottle body, with the neck kept cool — the operator removes them and loads them into the HGS blow station for stretching and blowing. The heater must run continuously and have sufficient output capacity to keep pace with the blow machine’s production rate.

The HGJ-B is selected for wide-mouth jar applications where the preform neck diameter exceeds the HGJ-CL’s 68mm maximum. For standard narrow-neck bottles, the EP-HGJ-CL is the appropriate heater. Browse all semi-automatic machines and heaters.

Technical Specifications

Complete Specifications — EP-HGJ-B
Parameter Unit Value
Power Supply Three-phase, four-wire
Output (Efficiency) bph 500–1,200
Using Power kW 5–8
Preform Wall Thickness mm 2.5–4.2
Preform Holder Positions 18/36
Max. Neck Diameter mm 130/65
Mold Height mm 160
Machine Size (L×W×H) mm 1,880 × 600 × 1,200
Machine Weight kg 400

⚠️ Note: The HGJ-B requires three-phase, four-wire power supply — unlike the HGS blow molding machines which use single-phase 220V. Confirm your facility’s electrical supply includes three-phase power before ordering. Request the full datasheet.

Heater Selection and Pairing Guidance

Select by Neck Diameter First

The only selection criterion between the HGJ-B and HGJ-CL is neck diameter. If your bottle’s neck diameter exceeds 68mm, the HGJ-B is required — the HGJ-CL’s preform holders cannot accommodate larger neck diameters. Wide-mouth jars, large-format cosmetic dispensers, and any container with a neck diameter above 68mm all require the HGJ-B. Standard narrow-neck bottles with neck diameter at or below 68mm use the HGJ-CL.

Heater Output Must Match or Exceed Blow Machine Output

The HGJ-B produces 500–1,200 heated preforms per hour. The HGS blow machine this heater is paired with must have an output rate at or below the heater’s rated capacity — otherwise the heater becomes the production bottleneck. For HGS machines with output rates above 1,200 bph at your specific bottle size, the HGJ-B may be insufficient and the higher-capacity HGJ-CL or a different configuration should be evaluated.

Three-Phase Power Required

The HGJ-B heater requires three-phase, four-wire power supply — different from the HGS blow machines which operate on single-phase 220V. If your facility has single-phase supply only, you will need to install a three-phase connection or a phase converter for the heater. Confirm your facility’s electrical supply before ordering the heater and the blow machine together.

Preform Wall Thickness Compatibility

The HGJ-B handles preforms with wall thickness of 2.5–4.2mm. Wide-mouth jar preforms are typically at the upper end of this range due to the larger volume and wider neck format. Confirm your preform specification — particularly wall thickness and overall preform weight — falls within the HGJ-B’s rated range before finalising the heater selection.

Frequently Asked Questions

Why does a semi-automatic machine need a separate preform heater? +
HGS machines do not include integrated preform heating. In the two-step RSBM process, preforms must reach 95–115°C before the blow station. Fully automatic machines integrate this zone internally; HGS semi-auto machines use a separate standalone HGJ heater. Without a heater, no bottles can be produced.
What does ‘130/65mm neck diameter’ mean on the HGJ-B? +
130mm outer diameter / 65mm inner bore. Wide-mouth jar preforms typically have a large outer neck support flange (up to 130mm) with an inner bore of ~65mm. Both dimensions must fit within the heater’s rated range for the preform holder to function correctly.
Can the HGJ-B be used with any HGS blow molding machine? +
Yes, subject to two conditions: blow machine output must not exceed HGJ-B’s 500–1,200 bph rated capacity; and your preform neck diameter must require the wide-mouth HGJ-B rather than the standard HGJ-CL. Heater and blow machine operate independently — the operator manually transfers heated preforms between units.
HGJ-B needs three-phase power but my HGS machine uses single-phase — is this a problem? +
A practical installation consideration, not a barrier. Both connections are made independently. If your facility has single-phase only, a three-phase connection needs to be installed for the heater, or a phase converter used. A standard electrical installation task — consult your local electrician for the specification.
How do I confirm whether HGJ-B or HGJ-CL is correct for my bottle? +
Send our engineering team your bottle drawing or preform specification with neck outer diameter, inner bore, and preform height. We confirm: HGJ-B for wide-mouth neck above 68mm; HGJ-CL for standard narrow-neck at or below 68mm.

Enquire About the EP-HGJ-B

For semi-automatic wide-mouth jar production lines — required alongside your HGS blow molding machine. Share your bottle’s neck diameter, preform wall thickness, and target production rate for a heater pairing confirmation.